Description
12F= Coalescing Filter Standard
2= 3/8″ Port
1= Twist Drain
E = Grade 6
C= Current
The contaminated air enters the element interior
and is forced through a thick membrane of
borosilicate glass fibers coated with epoxy (A).
Flow then passes through an outer structural
support and, at this stage, has removed up to
99.97% + of the sub-micron particles evident in the
contaminated air. These tiny droplets coalesce
together and are blotted from the filter surface by
the drain and release layers of non-woven glass
felt and rayon cloth. The drops now begin a
gravitational passage to the filter sump (B) where
they can be manually or automatically drained.
The clean, filtered air now passes through the
outer screen plastic net and out into the pneumatic
system. The Air Line Coalescing Filter removes
liquid aerosols and sub-micron particulate matter.
Collected liquids and particles in the “quiet zone”
should be drained before their level reaches a
height where they would be reentrained in the
flowing air. This can be accomplished by the
manual drain (C) which is actuated by twisting
knob (D) counterclockwise. On the 30 Series,
unscrew the drain valve (E) slightly until the liquid
begins to drain.
Features
• Removes liquid aerosols and sub-micron particles.
• Liquids gravitate to the bottom of the element
and will not re-enter the airstream.
• Oil free air for critical applications, such
as air gauging and pneumatic
instrumentation and controls.
• Interchangeable twist and automatic float drains.
• Pressure differential indicator standard.
• Shown with recommended metal bowl guard.
• High Flow: Grade 6 Element
3/8″ – 73 SCFM §
1/2″ – 75 SCFM §
3/4″ – 80 SCFM §